Split Ducts
This function splits Ducts in the selection into smaller pieces and creates Union Fittings in between of them.
The Default Standard length end Minimum length of the separated Ducts are set in the properties of the Ducts type.
Therefore, the following project parameters should be loaded into your project according the Witas template (Category Ducts):
For annex RME_BE_EN, these parameters are BE_G Standard length and BE_G Standard length_min
For annex RME_BE_NL, these parameters are: BE_G Standaardlengte and BE_G Standaardlengte min
For annex RME_BE_FR, these parameters are: BE_G Longueur standard_min and BE_G Longueur standard_min
Remarks:
The tool tries to create Ducts as much as possible according to the Default Standard length.
The remains at the end of the original Duct are averaged out.
The tool will never create a Duct smaller than the Standard minimum length.